Quick drying,
easy to apply, epoxy primer for protection of GRP against
osmosis. * Provides protection against osmosis in five coats (250
µm) * Useable down to 5°C * Fast drying allows multiple coat
application in a single day |
|
| Colour |
YPA212-Green,
YPA213-Grey |
| Finish |
Matt |
| Specific
Gravity |
1.4 |
| Volume
Solids |
45%
|
| Mix Ratio |
3:1 by volume
(as supplied) , Converter/Curing Agent - YPA214 |
| Typical Shelf
Life |
2 yrs |
| VOC (As
Supplied) |
464 g/lt |
| Unit Size |
750 ml 2.5
Lt |
|
|
|
Drying |
|
5°C |
15°C |
23°C |
35°C |
|
|
| Touch Dry
[ISO] |
4hrs |
2hrs |
1hrs |
30mins |
| Immersion |
24hrs |
18hrs |
12hrs |
8hrs |
| Pot Life |
10hrs |
5hrs |
3hrs |
2hrs |
|
|
Overcoating |
|
Substrate Temperature |
|
5°C |
15°C |
23°C |
35°C |
| Overcoated
By |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
|
|
| B.F.A. |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Cruiser |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Cruiser |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Cruiser
Eco/Cruiser Future |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Cruiser
Premium |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Cruiser UNO |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| CT
Kobberstoff |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Fabi |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Fabi
Eco/Waterways Future |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Fabi Skeppsmask
/ CT Kobber |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Gelshield 200 |
10hrs |
6mths |
5hrs |
6mths |
3hrs |
6mths |
2hrs |
6mths |
| Interspeed |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Interspeed
Aqua |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Interspeed
Kopervrij |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Interspeed
Ultra |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Lago Racing
II |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Micron |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Micron 55 |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Micron 66 |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Micron
Eco/Micron Future |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Micron Extra |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Micron
Kopervrij |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Micron Optima |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Micron WQ |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Navigator |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Prima |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Trilux |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Trilux (S) |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Trilux 33 |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Uni-Pro |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Veridian Tie
Coat |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
| Waterways (Eire
Only) |
10hrs |
24hrs |
5hrs |
9hrs |
3hrs |
7hrs |
1hrs |
5hrs |
|
|
Note:If maximum overcoating time is exceeded, sand
with 180-220 grade wet or dry paper. |
|
|
| Preparation |
BARE
GRP: Wash down with Super Cleaner, rinse with fresh water and
allow to dry. Sand with 180 grade (grit) paper. PREVIOUSLY
ANTIFOULED SURFACE: Remove using Interstrip. Wash down with
Super Cleaner, rinse with fresh water and allow to dry. Sand with
180 grade (grit) paper. EXPOSED LAMINATE: Patch prime
using Gelshield solventless epoxy. |
|
|
| Method |
Remove any dust
from the surface. Apply required number of coats, detailed in the
specification sheets (minimum 250 microns DFT). For ease, alternate
the grey and green colours starting and ending with grey. BILGES:
Apply 2 coats only provided there is a gelcoat on the inside of the
hull. If no gelcoat, use Gelshield solventless epoxy. |
|
|
| Hints |
Mixing Stir or shake individual components
thoroughly. Add Curing Agent to the Base, stir and leave for 10
minutes to allow bubbles to disperse. Thinner YTA061
Thinners No.7 Other Can be used down to 5°C but for
maximum performance, temperature should be above 10°C. |
|
|
| Some Important
Points |
New hulls must
be post-cured for a min. period of 4 weeks before applying Gelshield
200 . Do not apply direct to the exposed laminate. Do not use below
5°C. Ambient temperature should be minimum 5°C/40°F and maximum
35°C/95°F. Product temperature should be minimum 10°C and maximum
35°C. Substrate temperature should be minimum 5°C/40°F and maximum
35°C/95°F. |
|
|
| Compatibility/Substrates |
GRP Gelcoats
& cured laminate . It should not be used over any one pack
products. |
|
|
| Number of
Coats |
5 minimum by
brush (min. 250 µm DFT) |
|
|
| Coverage |
(Theoretical) -
9.10 (m²/lt) by brush |
|
(Practical) -
8.10 (m²/lt) by brush |
|
|
| Recommended
DFT |
50 microns dry
by brush
|
| Recommended
WFT |
110 microns wet
by brush |
|
|
| Application
Methods |
Brush, Roller
|
|
| Storage |
GENERAL INFORMATION: Exposure to air and
extremes of temperature should be avoided. For the full shelf life
of Gelshield 200 to be realised ensure that between use the
container is firmly closed and the temperature is between 5°C/40°F
and 35°C/95°F. Keep out of direct
sunlight. TRANSPORTATION: Gelshield 200 should be kept
in securely closed containers during transport and
storage.
|
|
|
| Safety |
GENERAL: Read
the label safety section for Health and Safety Information, also
available from our Technical Help Line. DISPOSAL: Do not discard
tins or pour paint into water courses, use the facilities provided.
It is best to allow paints to harden before disposal. Remainders
of Gelshield 200 cannot be disposed of through the municipal waste
route or dumped without permit. Disposal of remainders must be
arranged for in consultation with the authorities.
|
|
| IMPORTANT NOTES |
The
information given in this sheet is not intended to be exhaustive.
Any person using the product without first making further written
enquiries as to the suitability of the product for the intended
purpose does so at their own risk and we can accept no
responsibility for the performance of the product or for any loss or
damage (other than death or personal or injury resulting from
negligence) arising out of such use. The information contained in
this sheet is liable to modification from time to time in the light
of experience and our policy of continuous product
development. |
|
 , International , the
Akzo Nobel logo and other products mentioned in this publication are
trademarks of, or licensed to Akzo Nobel. |
|
Head
Office International Paint Ltd P O Box 20980 Oriel
House 16 Connaught Place London W2 2ZB United
Kingdom tel: +44 (0) 171 479 6000 fax: +44 (0) 171 479 6500 |
European
Region International Paint Ltd Stoneygate Lane Felling,
Gateshead Tyne & Wear NE10 0JY United Kingdom
tel:
+44 (0) 191 469 6111 fax: +44 (0) 191 438 3977 |
Asia
Region International Paint Singapore (Pte) Ltd 449 Tagore
Industrial Avenue 01-03 Hong Joo
Industrial Building Singapore 787820
tel: +65 6453
1981 fax: +65 6453 1778 |
Australasia
Region International Paint 115 Hyde Road Yeronga,
Brisbane Queensland 4104 Australia
tel: +61 (0) 7 3892
8866 fax: +61 (0) 7 3892 4287 |
North
America Region International Paint LLC 2270 Morris
Avenue Union New Jersey 07083 USA
tel: +1 (0) 908
686 1300 fax: +1 (0) 908 686 8545 |
South
America Region International Paint Rod Rap tavares, KM
18.5 Predio Administrativo 11 Butanta CEP 05577-300 Sao
Paulo, Brazil
tel: +55 (0) 11 3789 2000 fax: +55 (0) 11
3789 2200 | |